image
Flame Photometer

COOL FP-501 covers wide range of industrial application in food and beverages, cement sectors, pharmaceutical as well as agricultural, biological and clinical applications. The COOl FP-501 has developed by a team of experts with more than four decades of experience in designing, manufacturing and marketing analytical instruments

Large , bright , LCD display Navigation keypad on screen menu DotMatrix printer connection provision Inbuilt SMPS Removable Power cord

Simultaneous detection of four elements (Na, K, Ca, Li)
Easy to use, ignition and flame optimization
Result of four elements within 35 seconds
Unmatched accuracy and reliability
Flexible and customized as per user application
Data displayed in concentration units like ppm, meq etc
Auto fuel cut off after 30 minutes without pressing any key
Raw counts monitor for reliability of results
Built in curve for accurate results like TPA, PLA and BFC

Flame Photometry is an atomic emission technique which may be regarded as simplest of atomic spectroscopic methods very similar to flame test which is applied detection of alkali metals Micro Controller Based technology

Range of Operation

Sodium         0-30 ppm

Potassium  0-30 ppm

Calcium      0-30 ppm

Lithium        0-30 ppm

Barium         above 75 ppm

Detection

Element              Detection limits

Sodium               0.1 ppm

Potassium           0.1 ppm

Calcium              0.5 ppm

Lithium                0.1 ppm

Reproducibility        1ppm - + 10% of FSD

                             100ppm - + 5% of FSD

Display units/Modes     Selectable ppm, mEq or raw counts

Typical sample uptake rate   4ml/min

Sample consumption   Approx 1.5 ml for all four elements

Aspiration time         Automatic

Flame ignition         manual with built in ignition coil

Air supply              Oil and moisture free air @1.5 Bar

Fuel supply            LPG

Nebulizer              All metallic axial flow type

Safety protection      Auto fuel cut off when flame is unstained. Alarm provided

Calculation              TPA (Two point approximation) PLA (Piecewise linear Approximation) BFC( Best Fit curve for non linear working curve)

Method range        Upto 125 methods can be stored

Keyboard               22 Key membrane type keys for parameter selection

Display              Large, Backlit, Graphic LED(240 X 128 pixels)

Provision for printer     80 column Dot Matrix

Power                   AC mains 95-270 AC/50-60 HZ)

Weight                12 Kg( Approx)

Approx size (in mm)    430 X 300 X 235 (L X W X H)

Part Number

Description

250FPA05

Flame Photometer COOL FP-501 with

accessories